CAMP Engineering has upgraded its state-of-the-art technology with the best-in-class 10,000 frames per second camera system from RDI Technologies, to help with root cause analysis and troubleshooting structures, stationary and rotating equipment that are subjected to dynamic loads which often manifest in vibration related problems!
Some unique and innovative applications of video vibrometry follow (right-click on the videos and select “Loop” or “Repeat” for the best viewing):
Investigation into the natural frequencies of vibration of a low pressure turbine blades:
Investigation of FIV at a turbine control valve:
Overall Vibration: Displacements ODS
In the hands of an experienced professional, the HD Video Vibrometry technology allows rapid, very accurate and non-contact acquisition of vibration data which can then be queried for spectra, waveforms, and orbital plots as is customary required for vibration analysis … BUT … with the ability to amplify and animate the vibration with unparalleled clarity.
A variety of features allow, for example, to apply low-pass, high-pass, band-pass or band-stop filters to assist with problem diagnosis. Furthermore, image stabilization allows the extraction of real vibration relative to a vibrating reference such as camera shake, a structural target, or other similar reference included in the field of view.
One of, if not THE strongest feature, is visualization of the results. Any and all of the features mentioned above may be applied to the output for visualization and communication via still images, spectra, wave-forms or amplifying and controlling the playback speed of operating deflected shapes (ODS). The resolution is so good, that even opening and closing of cracks can be detected and displayed.
Contact us to help you detect and identify problem causes and contributors that heretofore may have escaped detection.
- The example below depicts a 30 Hz Motor driving a gearbox via belt and pulleys
- Gearbox drives a paddle mixer
- Results obtained from about 40 ft. away; i.e. non-contact
- ODS is constructed off 2 Mega-pixel HD Video
- Spectra and waveforms can be extracted from any point in the ODS
- Results can be filtered (band-pass, band-stop, high- and low-pass)
- Initial results available within minutes
- Same day preliminary diagnosis report
The 1st ODS initially shows a normal video of the equipment as would be observed by a human. After about 1 second, the video switches to an amplified and slowed down animation to reveal the actual vibration characteristics.
The 2nd and 3rd videos go directly to the amplified and slowed down animations of the vibration, filtered to only show what is going on at a specific frequency.
Overall Vibration: Velocities
4.7 Hz ODS